Home›Repair guides›Cummins/Onan›Changing Genset Frequency

Cummins/Onan — Changing Genset Frequency

Adjustments · Generator/voltage regulator

From a Cummins/Onan service manual — check it applies to your exact model before use.

Applies to: Cummins/Onan MDKAD, Cummins/Onan MDKAE, Cummins/Onan MDKAF

Before you start

  • Incorrect electrical connections/adjustments can cause equipment damage, severe injury or death. Turn off genset and disconnect battery before adjustments.

Procedure

  1. Identify new frequency and voltage.
  2. Replace AC output circuit breaker if necessary for new load.
  3. Move 60 Hz/50 Hz switch on regulator board to desired value.
  4. Readjust engine speed for new frequency: 50 Hz 1500 RPM, 60 Hz 1800 RPM under no-load and full-load.
  5. Apply maximum rated load and adjust frequency fine adjust screw to desired frequency.
  6. Remove load and check no-load frequency is within 3 Hz of full-load frequency.
  7. Tighten lock nut.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 50 Hz: 1500 RPM
  • 60 Hz: 1800 RPM

Full service-parts list: Cummins/Onan MDKAD →, Cummins/Onan MDKAE →, Cummins/Onan MDKAF →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.