Cummins/Onan — Breaker Points Replacement and Adjustment
Maintenance
From a Cummins/Onan service manual — check it applies to your exact model before use.
Applies to: Cummins/Onan NHC-NHCV engine
Procedure
- Remove spark plugs and breaker box cover.
- Rotate crankshaft clockwise until points are fully open.
- Remove condenser screw and detach condenser lead and coil lead screw.
- Remove two Allen screws and lift breaker assembly from engine.
- Replace condenser and point assembly with new parts and reinstall.
- Rotate crankshaft clockwise until points fully open.
- Set point gap to 0.016 inch (0.41 mm) by adjusting socket head screw.
- Replace breaker box cover, coil wire, spark plugs, and spark plug cables.
Tools required
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Point gap: 0.016 inch (0.41 mm) equivalent to 20° BTC
Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.