Home›Repair guides›Cummins/Onan›Battery Connections (prior to Onan serial number 661047)

Cummins/Onan — Battery Connections (prior to Onan serial number 661047)

Installation

From a Cummins/Onan service manual — check it applies to your exact model before use.

Browse Cummins/Onan generators & specs →

Procedure

  1. Connect positive post of one 12 volt battery to forward terminal of series-parallel switch.
  2. Connect negative post of same battery to grounded terminal of start solenoid.
  3. Connect positive post of second 12 volt battery to terminal on side of engine starting motor.
  4. Connect negative post of same battery to rear terminal of series-parallel switch.

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.