Home›Repair guides›Cummins/Onan›Battery Charging Winding Tests

Cummins/Onan — Battery Charging Winding Tests

Testing & diagnosis

From a Cummins/Onan service manual covering: 02SX1N1A, 04SX1N, 04SX1N1A, 04SX1N1B, 04SX1N2B, 04SX1N3B, 04SX1N4B, 06SX1N, 06SX1N1A, 06SX1N1B, 06SX1N2B, 06SX1N3B…. Check it applies to your exact model before use.

Browse Cummins/Onan generators & specs →

Procedure

  1. Remove lead from battery polarity reconnection block to ammeter at ammeter.
  2. Install DC voltmeter between lead and ground.
  3. At governed engine speed, average DC output should be 19 to 21 volts.
  4. If output defective, test for open circuit or grounding in leads and windings.
  5. If leads defective, replace them. If winding defective, replace stator.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 19 to 21 volts DC average at governed speed

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.