Cummins/Onan 5.0GenSet ES 1348 — Battery Care and Maintenance
For the Cummins/Onan 5.0GenSet ES 1348.
Applies to: Cummins Onan 5 0Genset Es 1348
Before you start
- Lead acid batteries emit highly explosive hydrogen gas which can be ignited by electrical arcing or a lighted cigarette. Do not smoke while charging or servicing batteries.
Procedure
- Keep the battery case clean and dry.
- Make sure the battery cable connections are clean and tight.
- Coat the battery terminals with a mineral grease or petroleum jelly to reduce corrosion and oxidation.
- Identify each battery cable to be positive or negative before making any connection. Always connect the ground (negative) cable last.
- Maintain the electrolyte level by adding water (drinking quality or better) as needed for filling to split level marker.
- The standard battery charger will provide a constant charge rate of 1 amp during alternator operation. If the alternator is not operated often enough to keep the battery charged, connect battery to a separate charger at least once a month to maintain a full charge.
Tools required
- Mineral grease or petroleum jelly
Source: manual:919-0120 Onan P-Series (spec J) Portable Genset Operators manual (12-1981).pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.