For the Cummins/Onan B43 / B48, from the Cummins/Onan operator's manual.
Applies to: Cummins/Onan B48
Procedure
- Run the engine until it reaches normal operating temperature.
- Turn off the fuel supply and run the engine until it stops.
- Drain oil from oil base while warm; refill with fresh crankcase oil and attach a tag stating viscosity used.
- Remove spark plugs; pour 1 ounce (2 tablespoons or 28 grams) of rust inhibitor or SAE #50 oil into the cylinders, crank a few times, reinstall plugs.
- Service air cleaner as outlined in Maintenance.
- Clean governor linkage and protect by wrapping with a clean cloth.
- Plug exhaust outlet to prevent entrance of moisture, dirt, bugs.
- Wipe entire unit; coat rustable parts with a light film of grease or oil.
- Provide a suitable cover for the entire unit.
- If battery equipped, disconnect and follow standard battery storage procedure.
Specs & values
- 1 ounce (2 tablespoons or 28 grams) rust inhibitor or SAE #50 oil per cylinder