Home›Repair guides›Cummins/Onan›Exerciser Clock Adjustment

Cummins/Onan ATUC A 800 - 4X / 111 — Exerciser Clock Adjustment

Adjustments

For the Cummins/Onan ATUC A 800 - 4X / 111, from the Cummins/Onan service manual.

Browse Cummins/Onan generators & specs →

Procedure

  1. Open the right cabinet door of the automatic transfer switch.
  2. Move the operation selector switch on engine control to STOP.
  3. Install a trip pin (left-hand thread) in the inside row of holes on the large dial for the start time.
  4. Place a trip pin in the outside row of holes on the large dial to stop the generator set.
  5. Install a trip pin in the small spoked wheel for every day no exercise is desired.
  6. Rotate the large dial clockwise until the correct time aligns with the time pointer.
  7. Align the small spoked wheel with the correct day at its pointer.
  8. Move the operation selector switch on engine control to RMT.
  9. Close the cabinet door.

Tools required

  • Trip pins (left-hand thread) Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Operate the generator set for at least 30 minutes each week. Exercising for one long period is better than several short periods.

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.