Cummins/Onan — Assemble Centrifugal Switch
Repair & overhaul
From a Cummins/Onan service manual — check it applies to your exact model before use.
Applies to: Cummins/Onan DJB engine
Procedure
- Install the spacer on the shaft and install the shaft assembly into the gear case, matching it with the cam gear.
- Install the spring and plunger into the end of the shaft.
- Install the breaker plate.
- Install the plunger and diaphragm.
- Install the breaker points on the breaker plate and set the gap at 0.040 inch.
- Install the switch cover and reconnect the battery.
Specs & values
- Breaker point gap 0.040 in
Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.