Cummins/Onan — Adjustment:
For these Cummins/Onan models: BGD, NHD.
Applies to: Cummins Onan Bgd
Procedure
- 1. Run the genset at least 15 minutes at 50% to 75% of
- 2. Remove the load and let the set stabilize 10 to 15
- 3. Read the gensetfrequency. With no load,frequency
- 4. Turn the speed nut until the no-load frequency is
- 5. Slowly turn the idle stop screw in to increase the
- 6. Turn the speed nut in until the no-load frequency is
- 7. Connect rated load.
- 9. Check frequency with rated load connected.
- 8. Check output voltage. Service the generator (Sec-
- 10. Check governor response under no load, 1 14 load,
Source: manual:965-0529 Onan BGD BGDL NHD (spec A-G) Genset Service manual (05-2009).pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.