Home›Repair guides›Cummins/Onan›Adjusting the Reverse Current (Charge) Relay

Cummins/Onan — Adjusting the Reverse Current (Charge) Relay

Adjustments · Reverse current relay

From a Cummins/Onan owner's manual — check it applies to your exact model before use.

Browse Cummins/Onan generators & specs →

Procedure

  1. Clean the contact points with hard finish paper.
  2. Replace the relay with a new one if cleaning does not remedy the trouble.
  3. Set spring tension so points open at 12.6 volts and close at 15.4 volts.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Points open at 12.6 volts
  • Points close at 15.4 volts

Source: Cummins/Onan owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.