Home›Repair guides›Cummins/Onan›Adjusting Quad Winding Generator Voltage Using Control Switch

Cummins/Onan — Adjusting Quad Winding Generator Voltage Using Control Switch

Adjustments · Quad winding generator / voltage adjustment

From a Cummins/Onan service manual — check it applies to your exact model before use.

Applies to: Cummins/Onan MDDC, John Deere 4045TFM engine, John Deere 6068TFM engine

Procedure

  1. Start the generator set and let voltage and frequency stabilize for 5 to 10 seconds; disconnect all loads.
  2. Rapidly press START 6 times during the first minute after start up to enter voltage adjust mode.
  3. To adjust voltage up, press and quickly release START (approx. 0.6 volts per press).
  4. To adjust voltage down, press and hold START for about 1 second.
  5. Wait about 20 seconds for the amber lamp to stop blinking, then press STOP to save.
  6. Restart the generator set and check voltage.

Specs & values

  • Each press/release changes voltage approximately 0.6 volts.

Full service-parts list: Cummins/Onan MDDC →, John Deere 4045TFM engine →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.