Before you start

  • Leaks can lead to explosive accumulations of gas.

Procedure

  1. Push the genset line circuit breakers OFF (Figure 4).
  2. Remove the air filter, start the genset and spray an engine fogger (OnaGard) into the carburetor; then stop the genset.
  3. Change the engine oil and oil filter, and the air filter if dirty.
  4. Disconnect the battery cables (negative first) and store the battery per the manufacturer's recommendations.
  5. Close the fuel supply valve; cap or plug any unused fuel line if the genset is removed from the premises.