For the Cummins/Onan 5.6TGHAA11381C, from the Cummins/Onan service manual.

Applies to: Cummins/Onan TGHAA

Before you start

  • Careless handling can damage the insulation on the stator windings.

Procedure

  1. Disconnect the negative battery cable and then the battery cables from the genset.
  2. Remove the top panel of the genset housing.
  3. Disconnect the gas hose and regulator pressure balance hose at the carburetor.
  4. Disconnect the crankcase breather hose at the air cleaner adapter.
  5. Remove the air cleaner and adapter from the carburetor.
  6. Remove the brush block assembly or insert a stiff wire to hold the brushes up and out of the way (Figure 69).
  7. Disconnect wiring to AC output, switches, sensors, fuel solenoid, governor actuator, de-icer, ignition B+ and ground strap and the four sealed connectors.
  8. Remove the two generator vibration isolator center-bolts and support the engine with a piece of two-by-four lumber.
  9. Remove the four stator housing bolts and pull the housing straight back taking care not to scrape stator windings.

Full service-parts list: Cummins/Onan TGHAA →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.