Home›Repair guides›Cummins/Onan›Voltage Regulator Test

Cummins/Onan 3.6MKY / 4MKY — Voltage Regulator Test

Testing & diagnosis · Voltage regulator VR1

For the Cummins/Onan 3.6MKY / 4MKY, from the Cummins/Onan service manual.

Applies to: Cummins/Onan 3.6MKY, Cummins/Onan 4MKY

Procedure

  1. Disengage the J4 wiring connector and remove the voltage regulator.
  2. Set the meter on Diode Check; test between terminal pairs 5-9, 7-9, 10-9, 11-9, 12-9, 10-5, 5-11, 5-12, and 5-3.
  3. Connect the positive meter lead to the first terminal of each pair.
  4. Replace the regulator if any reading indicates a short or open, except pair 10-5 which should be open.

Tools required

  • Multimeter with diode checking (Fluke 73 or equivalent) Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Pair 10-5 should indicate open

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.