Cummins/Onan 3.6MKY / 4MKY — Starter Voltage Check

Testing & diagnosis · Electric starter

For the Cummins/Onan 3.6MKY / 4MKY, from the Cummins/Onan service manual.

Applies to: Cummins/Onan 3.6MKY, Cummins/Onan 4MKY

Procedure

  1. Connect a voltmeter between the start relay output terminal (starter motor lead side) and ground.
  2. Press the start switch.
  3. If approximately 12 VDC is present but the starter does not crank, the starter is defective.
  4. If no voltage, check the battery, start solenoid and control wiring.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • approximately 12 VDC

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.