Home›Repair guides›Cummins/Onan›Operating on gasoline after gas operation

Cummins/Onan 1B Series — Operating on gasoline after gas operation

Operation · Fuel system

For the Cummins/Onan 1B Series, from the Cummins/Onan owner's manual.

Browse Cummins/Onan generators & specs →

Procedure

  1. Shut off gas supply.
  2. Turn float stop screw all the way in until it seats.
  3. Make sure choke is free to operate.
  4. Open gasoline shutoff valve.
  5. Start engine following applicable instructions.
  6. Carburetor has fixed jets, not adjustable for gasoline.
  7. If speed/voltage unsteady, adjust governor or clean fixed jets.

Source: Cummins/Onan owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.