Before you start

  • Over choking causes hard starting and excessive wear.

Procedure

  1. Pull choke out all the way.
  2. Wind starting rope clockwise around rope sheave at front of plant.
  3. Give a strong steady pull the full length of the rope.
  4. If plant fails to start, push choke in as required and repeat.
  5. As engine starts to fire, push choke gradually in until fully open when plant is thoroughly warmed up.
  6. If plant is still warm, choking is not necessary.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.