Home›Repair guides›Cummins/Onan›Load Sensor Board Component Tests (Spec A and B)

Cummins/Onan 15.0 HA / 7.5 HA — Load Sensor Board Component Tests (Spec A and B)

Testing & diagnosis

For the Cummins/Onan 15.0 HA / 7.5 HA, from the Cummins/Onan service manual.

Browse Cummins/Onan generators & specs →

Procedure

  1. Place the control in the MANUAL position if the sensor board is mounted in the control.
  2. Check components starting at the left side of the board with an ohmmeter set at R X 100 scale.
  3. Check the first resistor, the rheostat, the rectifier, the Zener diode, the transistor and the remaining resistors.
  4. Replace any component that does not meet its specified resistance.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.