Home›Repair guides›Cummins/Onan›Testing the Armature for an Open Circuit

Cummins/Onan 1400 / 2.0UF-232S/32 — Testing the Armature for an Open Circuit

Testing & diagnosis · Armature / commutator

For the Cummins/Onan 1400 / 2.0UF-232S/32, from the Cummins/Onan operator's manual.

Applies to: Cummins/Onan 1400

Procedure

  1. Place the armature in the growler which is connected to alternating current.
  2. Rub a smooth steel blade (back edge of a hacksaw blade) across the segments of the commutator.
  3. A spark should occur as the blade contacts two adjacent segments, indicating the circuit is complete.
  4. Rotate the armature just enough to test the next two segments and continue until tested completely around.
  5. If no spark occurs, the winding between those two segments is open circuited.

Tools required

  • Armature growler (AC) Amazon
  • Smooth steel blade / hacksaw blade Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Full service-parts list: Cummins/Onan 1400 →

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.