Home›Repair guides›Cummins/Onan›Testing the Armature for a Grounded Circuit

Cummins/Onan 1400 / 2.0UF-232S/32 — Testing the Armature for a Grounded Circuit

Testing & diagnosis · Armature / commutator

For the Cummins/Onan 1400 / 2.0UF-232S/32, from the Cummins/Onan operator's manual.

Applies to: Cummins/Onan 1400

Procedure

  1. Use an ohmmeter and test prods.
  2. Place one test prod on the commutator and the other prod on a bare clean part of the generator frame or armature shaft.
  3. The prods must make good electrical contact.
  4. If the ohmmeter shows continuity, the armature is grounded.
  5. Replace a grounded armature with a new one.

Tools required

  • Ohmmeter and test prods Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Full service-parts list: Cummins/Onan 1400 →

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Cummins/Onan repair guides →