Home›Repair guides›Cummins/Onan›Changing Generator Shaft Rotation - 2.0S-232/32A (Counterclockwise to Clockwise)

Cummins/Onan 1400 / 2.0UF-232S/32 — Changing Generator Shaft Rotation - 2.0S-232/32A (Counterclockwise to Clockwise)

Adjustments · Control box terminal A and B+, generator field lead F2

For the Cummins/Onan 1400 / 2.0UF-232S/32, from the Cummins/Onan operator's manual.

Applies to: Cummins/Onan 1400

Procedure

  1. Connect wires to control as shown for clockwise rotation in Figure 6.
  2. Disconnect generator field lead F2 from control box terminal A.
  3. Touch this lead momentarily to control box terminal B+, making sure a good battery is used; a definite spark should occur.
  4. Reconnect F2 lead to A terminal of control box.
  5. Check to see that blower scroll is installed according to clockwise rotation.
  6. If changing rotation back from clockwise to counterclockwise, F1 generator lead will be connected to control terminal A; repeat above steps.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Full service-parts list: Cummins/Onan 1400 →

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.