Home›Repair guides›Cummins/Onan›Air Cleaner Service

Cummins/Onan 12.0 RDJC — Air Cleaner Service

Maintenance

For the Cummins/Onan 12.0 RDJC, from the Cummins/Onan operator's manual.

Applies to: Cummins/Onan RDJC

Parts for this job

Part numbers from the service-parts list for Cummins/Onan RDJC. Verify against your serial number before ordering; some links are affiliate links.

Procedure

  1. Remove pre-cleaner and wash out dirt; dry and re-install.
  2. Loosen clamp and remove end cover.
  3. Remove thumbscrew and take out element.
  4. Wash element in detergent and water (use new element after 6 washings or every 200 hours).
  5. Dry and re-install.
  6. Remove air cleaner baffle from cover, wash out dirt, and re-install in cover.
  7. Install cover with TOP up and tighten clamp.

Specs & values

  • Element replaced every 200 hours

Full service-parts list: Cummins/Onan RDJC →

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.