Cummins — 23. Install but do not tighten the four lock washers and
For these Cummins models: GTA38, GTA38, GTA50, GTA50.
Browse Cummins generators & specs →
Procedure
- 25. Tighten the four pump to pump drive cap-screws.
- Torque Value: 60 Nem [45 ft-lb]
- 26. Tighten the four adapter plate cap-screws that hold
- the plate to the cylinder block.
- Torque Value: 40 Nem [30 ft-Ib]
- Install the Water Pump Inlet Housing
- 27. Install the o-ring seal in the groove on the inlet hous-
- ing. Us vegetable oi! to lubricate the seal.
- 28. Install the housing in the bore in the water pump.
- 29. Align the holes. Install the two lock-washers and
- cap-screws in the top and outside cap- screw holes.
- 30, Tighten the cap-screws only enough to hold the
- parts together.
Tools required
- 26. Tighten the four adapter plate cap-screws that hold
Specs & torque values