HomeRepair guides23. Install but do not tighten the four lock washers and

Cummins — 23. Install but do not tighten the four lock washers and

For these Cummins models: GTA38, GTA38, GTA50, GTA50.

Browse Cummins generators & specs →

Procedure

  1. 25. Tighten the four pump to pump drive cap-screws.
  2. Torque Value: 60 Nem [45 ft-lb]
  3. 26. Tighten the four adapter plate cap-screws that hold
  4. the plate to the cylinder block.
  5. Torque Value: 40 Nem [30 ft-Ib]
  6. Install the Water Pump Inlet Housing
  7. 27. Install the o-ring seal in the groove on the inlet hous-
  8. ing. Us vegetable oi! to lubricate the seal.
  9. 28. Install the housing in the bore in the water pump.
  10. 29. Align the holes. Install the two lock-washers and
  11. cap-screws in the top and outside cap- screw holes.
  12. 30, Tighten the cap-screws only enough to hold the
  13. parts together.

Tools required

  • 26. Tighten the four adapter plate cap-screws that hold

Specs & torque values

  • 45 ft-lb

Source: manual:Cummins Gas GTA38-50 Manual 1999 (2).pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.