Chicago Pneumatic — Installation

Installation · Filter

From a Chicago Pneumatic service manual — check it applies to your exact model before use.

Before you start

  • Do not allow sealant to enter interior of unit.
  • Drain may fail to operate if the tube I.D. is less than 5mm (3/16").

Procedure

  1. Shut-off air pressure. Install filter in air line vertically (bowl down), with air flow in direction of arrow on body.
  2. Install upstream of regulators, lubricators, and cycling valves; as close as possible to the air supply when used as a main line filter; as close as possible to the device being serviced when used as
  3. Connect piping to proper ports using pipe thread sealant on male threads only. Do not allow sealant to enter interior of unit.
  4. Push bowl, or bowl with guard, into body and turn fully clockwise before pressurizing.
  5. Flexible tube with 5mm (3/16") minimum I.D. can be connected to the automatic drain. Avoid restrictions in the tube.

Specs & values

  • Port size: 1/2"
  • Thread form: PTF, or ISO G
  • Automatic drain connection: 1/8"
  • Flexible tube minimum I.D.: 5mm (3/16")

Source: Chicago Pneumatic service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.