Chicago Pneumatic — Compressed Air Filter Assembly
A Chicago Pneumatic service procedure — check it applies to your exact model before use.
Browse Chicago Pneumatic generators & specs →
Procedure
- Lubricate o-rings.
- Assemble filter as shown on the exploded view.
- Push bowl, or bowl with guard, into body and turn fully clockwise.
Tools required
- Torque wrench
Specs & torque values
- Screw (Item 2) torque: 2.8 to 3.9 N-m (25 to 35 Inch-Pounds)
- Nut (Item 41) torque: 2.3 to 2.8 N-m (20 to 25 Inch-Pounds)
- Screw (Item 43) torque: 1.7 to 3.4 N-m (15 to 30 Inch-Pounds)
- Baffle (Item 49), Louver (Item 51) torque: 1.1 to 2.2 N-m (10 to 20 Inch-Pounds)
Source: manual:8940169127.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.