Champion — ATS200 connection to Electric Range with LCM
Installation
From a Champion service manual covering: 100174, 100177, 100199. Check it applies to your exact model before use.
Procedure
- Use Load Control Module (LCM) to manage high-demand appliances
- Connect relay (up to 8) between circuit breaker and appliance through LCM
- LCM manages appliance startup to prevent generator overload
Source: Champion service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.