Caterpillar VR6 — Voltage - Adjust
Adjustments · VR6 voltage regulator
For the Caterpillar VR6, from the Caterpillar service manual.
Browse Caterpillar generators & specs →
Procedure
- Rotate voltage adjustment clockwise to increase voltage.
- Rotate voltage adjustment counterclockwise to decrease voltage.
- When jumper is installed between terminals 4 and 7, vary nominal generator voltage over operating range using voltage adjustment.
- To use external voltage adjust rheostat: stop genset; remove jumper between terminals 4 and 7.
- Connect external voltage adjust rheostat across terminals 6A and 7; rheostat should be rated at 10 kOhm.
- Turn voltage adjustment on regulator fully clockwise for external adjustment to operate properly.
Specs & values
- External voltage adjust rheostat rated at 10 kOhm
Source: Caterpillar service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.