Home›Repair guides›Caterpillar›Voltage - Adjust

Caterpillar VR6 — Voltage - Adjust

Adjustments · VR6 voltage regulator

For the Caterpillar VR6, from the Caterpillar service manual.

Browse Caterpillar generators & specs →

Procedure

  1. Rotate voltage adjustment clockwise to increase voltage.
  2. Rotate voltage adjustment counterclockwise to decrease voltage.
  3. When jumper is installed between terminals 4 and 7, vary nominal generator voltage over operating range using voltage adjustment.
  4. To use external voltage adjust rheostat: stop genset; remove jumper between terminals 4 and 7.
  5. Connect external voltage adjust rheostat across terminals 6A and 7; rheostat should be rated at 10 kOhm.
  6. Turn voltage adjustment on regulator fully clockwise for external adjustment to operate properly.

Specs & values

  • External voltage adjust rheostat rated at 10 kOhm

Source: Caterpillar service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.