Caterpillar — Voltage Regulator Resistance Verification and Modification
A Caterpillar service procedure — check it applies to your exact model before use.
Browse Caterpillar generators & specs →
Procedure
- Verify resistance does not exceed 0.25 Ohm at both primary and secondary
- When using combination of pre- and post-May 1984 regulators (tan and black A1s), modify newer models to electrically match earlier models
- Add link from center to clockwise end of droop potentiometer as shown in Figure 8
Specs & torque values
- 0.25 Ohm maximum at both primary and secondary
Source: manual:Cat Zero Droop Volt for Par Op lekx8142.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.