Caterpillar — Turbocharger - Clean (Cleaning with Dry Particles)
Maintenance
From a Caterpillar owner's manual covering: 1YG1-Up, 4CG1-Up, G3612, G3616. Check it applies to your exact model before use.
Applies to: Caterpillar G3612, Caterpillar G3616
Procedure
- Ensure purge valve (2) is closed. Ensure cap (3) secure. Open gate valve (4).
- Open air valve (1) to remove deposits from connecting pipe. After three minutes, close air valve (1). Close gate valve (4).
- Open purge valve (2) to relieve pressure. Close purge valve (2).
- Remove cap (3). Pour 0.5 L (0.5 qt) of particles into container. Tighten cap (3).
- Ensure purge valve (2) closed. Reduce engine output so exhaust temperature before turbine is less than 577 °C (1070 °F).
- Open gate valve (4). Open air valve (1).
- After 60 to 90 seconds, close air valve (1). Close gate valve (4).
- Open purge valve (2) to relieve pressure. Close purge valve (2).
Specs & values
- Exhaust temperature before turbine must be less than 577 °C (1070 °F)
- Pour 0.5 L (0.5 qt) of particles
Source: Caterpillar owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.