Caterpillar — Stopping the Engine (Manual Operation)
Operation · Control Panel
From a Caterpillar owner's manual covering: 7C-1000, 9Y-1300, 9Y-1400, SR4. Check it applies to your exact model before use.
Applies to: Caterpillar SR4
Procedure
- Remove the load from the engine.
- If high idle cool down at no load is desired, turn the Engine Control Switch (ECS) to the Stop position for the preset or programmed cool down time.
- Reduce engine speed to Low idle (approximately 2/3 the full load speed of 60 Hz units or 4/5 full load speed of 50 Hz units).
- While the engine is at low idle, measure the engine oil level; maintain between the Add and Full marks on the dipstick.
- Allow the engine to cool down while running at low idle (approximately five minutes), then turn the Engine Control Switch to the Off-Reset position.
Specs & values
- Low idle approximately 2/3 the full load speed of 60 Hz units or 4/5 full load speed of 50 Hz units
Source: Caterpillar owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.