Home›Repair guides›Caterpillar›Steering Column Spline (HMU Steering) - Lubricate

Caterpillar — Steering Column Spline (HMU Steering) - Lubricate

Maintenance

From a Caterpillar owner's manual — check it applies to your exact model before use.

Browse Caterpillar generators & specs →

Before you start

  • Crushing Hazard. Connect the steering frame lock between front and rear frames before servicing the machine in the articulation area.
  • Do not disconnect any hydraulic lines from the metering pump.

Procedure

  1. Remove five bolts and the panel from each side of the machine.
  2. Support the metering pump. Do not loosen the hose couplings.
  3. Loosen the four bolts that hold the pump.
  4. Lower the pump in order to expose the splines.
  5. Clean the male splines on the steering column. Clean the female splines in the pump.
  6. Apply proper grease to the splines.
  7. Push the pump into position.
  8. Tighten the four bolts that hold the pump.
  9. Test the steering system.

Specs & values

  • Refer to Lubricant Viscosities for selecting the proper grease

Source: Caterpillar owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Caterpillar repair guides →