Caterpillar — Rocker Arm - Disassemble
A Caterpillar service procedure — check it applies to your exact model before use.
Browse Caterpillar generators & specs →
Before you start
- Keep all parts clean from contaminants.
- Check the condition of all components. Replace any worn or damaged components with new parts.
- Do not reuse the O-ring seals on the rocker arm adjustment screws if the buttons have been removed from the adjustment screws.
Procedure
- Start By: Remove the rocker arms and the rocker shaft.
- Remove valve rocker arms (7) and unit injector rocker arm (2) from rocker shaft (3).
- Remove button (6) from adjuster screw (5) in valve rocker arm (7).
- Remove button (4) from adjuster screw (1) in unit injector rocker arm (2).
- Repeat the steps above for the remaining rocker arm assemblies.
Source: manual:3456 Disassembly and Assembly.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.