HomeRepair guidesRocker Arm - Disassemble

Caterpillar — Rocker Arm - Disassemble

A Caterpillar service procedure — check it applies to your exact model before use.

Browse Caterpillar generators & specs →

Before you start

  • Keep all parts clean from contaminants.
  • Check the condition of all components. Replace any worn or damaged components with new parts.
  • Do not reuse the O-ring seals on the rocker arm adjustment screws if the buttons have been removed from the adjustment screws.

Procedure

  1. Start By: Remove the rocker arms and the rocker shaft.
  2. Remove valve rocker arms (7) and unit injector rocker arm (2) from rocker shaft (3).
  3. Remove button (6) from adjuster screw (5) in valve rocker arm (7).
  4. Remove button (4) from adjuster screw (1) in unit injector rocker arm (2).
  5. Repeat the steps above for the remaining rocker arm assemblies.

Source: manual:3456 Disassembly and Assembly.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.