Home›Repair guides›Caterpillar›Fuel System - Prime (3056E)

Caterpillar — Fuel System - Prime (3056E)

Maintenance

From a Caterpillar owner's manual covering: 3054E, 3056E, C12. Check it applies to your exact model before use.

Browse Caterpillar generators & specs →

Before you start

  • Do not crank the engine continuously for more than 30 seconds. Allow the starting motor to cool for two minutes.

Procedure

  1. Loosen nut (2) on the fuel injection pump (1).
  2. Operate the priming lever (4) on the priming pump (3) until fuel flows out of nut (2) free of air.
  3. Tighten nut (2) to a torque of 23 N·m (17 lb ft).
  4. If the fuel line for the air inlet heater has been drained, loosen nut (5) and prime until free of air.
  5. Tighten nut (5) to a torque of 22 N·m (16 lb ft).
  6. Loosen flare nuts (6) for the high pressure fuel lines on all of the fuel injection nozzles.
  7. Operate the starting motor until the fuel is free of air.
  8. Tighten flare nuts (6) to a torque of 27 N·m (20 lb ft).
  9. Operate the engine at low idle for a minimum of five minutes.

Specs & values

  • Nut (2) torque: 23 N·m (17 lb ft)
  • Nut (5) torque: 22 N·m (16 lb ft)
  • Flare nuts (6) torque: 27 N·m (20 lb ft)

Source: Caterpillar owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Caterpillar repair guides →