Home›Repair guides›Caterpillar›Fuel System - Prime (3054E)

Caterpillar — Fuel System - Prime (3054E)

Maintenance

From a Caterpillar owner's manual covering: 3054E, 3056E, C12. Check it applies to your exact model before use.

Browse Caterpillar generators & specs →

Before you start

  • Damage to the fuel injection pump, battery and starter motor can occur if the starter motor is used excessively.

Procedure

  1. Turn the key switch to the RUN position. Leave the key switch in the RUN position for three minutes.
  2. Turn the key switch to the OFF position.
  3. Loosen flare nuts (1) for the high pressure fuel lines on all of the fuel injection nozzles.
  4. Operate the starting motor and crank the engine until the fuel is free of air.
  5. Tighten flare nuts (1) to a torque of 30 N·m (22 lb ft).
  6. Operate the engine at low idle for a minimum of five minutes.

Specs & values

  • Flare nut (1) torque: 30 N·m (22 lb ft)
  • Do not crank the engine continuously for more than 30 seconds.

Source: Caterpillar owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.