Home›Repair guides›Caterpillar›Final Detensioning

Caterpillar — Final Detensioning

Maintenance · Tension cylinders and implement valve

From a Caterpillar service manual covering: Challenger 65, Challenger 70, Challenger 75, Challenger 85, Challenger 95. Check it applies to your exact model before use.

Browse Caterpillar generators & specs →

Before you start

  • Make sure the front axle pin is free of debris and lubricated before detensioning; failure may damage the axle, pin, or saddle.
  • On early models with a crossover hose, keep the rear hose section in an oil bucket.

Procedure

  1. Use the short hose to connect the LH and RH tensioners together.
  2. Use the long hose to connect to the machine implement control valve at the rear.
  3. Check the front axle area for debris; lubricate the back side of the front axle pin.
  4. With the tractor in neutral, depress the clutch, start and run at idle.
  5. Move the correct implement valve lever to extend the tension cylinders fully back on both sides.
  6. Move the implement lever to the hold position and stop the engine.

Tools required

  • Camso Detensioning Hose Kit Amazon
  • Oil, soap or grease Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Both sides must extend all the way back

Source: Caterpillar service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.