Home›Repair guides›Caterpillar›Cooling System Water Temperature Regulator - Replace

Caterpillar — Cooling System Water Temperature Regulator - Replace

Repair & overhaul · Thermostat

From a Caterpillar owner's manual — check it applies to your exact model before use.

Browse Caterpillar generators & specs →

Procedure

  1. Open engine access door.
  2. Drain coolant from machine.
  3. Loosen hose clamp and remove hose from thermostat housing.
  4. Remove two bolts from thermostat housing. Remove housing.
  5. Remove seal and thermostat from housing.
  6. Install new thermostat and new seal. Install housing on cylinder head.
  7. Install hose. Tighten hose clamp.
  8. Refill cooling system.
  9. Close engine access door.

Specs & values

  • Replace interval: every 3000 Service Hours or 2 years

Source: Caterpillar owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.