Home›Repair guides›Caterpillar›Load Bank Test

Caterpillar C6.6 / D125 — Load Bank Test

Testing & diagnosis · Generator

For the Caterpillar C6.6 / D125, from the Caterpillar manual.

Applies to: Caterpillar D125, Caterpillar C6.6 engine

Procedure

  1. Warm up
  2. Start and record no-load readings
  3. Apply load and record readings at 15 min
  4. Record readings at 30 min
  5. Record readings at 45 min
  6. Record readings at 1 hour
  7. Cool down and record readings

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 125 kW
  • 347 A
  • 208 V
  • 60 Hz
  • Power Factor 1

Full service-parts list: Caterpillar D125 →

Source: Caterpillar manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.