  1. Be sure the seal is seated in the groove at the bottom surface of the Jacobs spacer.
  2. Leave a .375 in. (9.5 mm) gap between each end of the gasket and the spacer.
  3. Install the three Jacobs spacers on the valve cover base.
  4. Install the terminal leadout assemblies into the spacers and tighten with a six point box wrench until seated against spacer.
  5. Connect the solenoid lead wires to the terminal leadouts in the three spacers.