Caterpillar C317 — Slave Piston Adjustment

Adjustments

For the Caterpillar C317, from the Caterpillar service manual.

Browse Caterpillar generators & specs →

Procedure

  1. Make the slave piston adjustments with the engine stopped and cold; exhaust valves must be closed on the cylinder to be adjusted.
  2. Insert the proper Jacobs feeler gauge between the slave piston and the actuating pin in the valve bridge adjusting screw.
  3. Turn the slave piston adjusting screw in until a slight drag is felt on the feeler gauge.
  4. Hold the adjusting screw and tighten the locknut to 25 lbft. (35 N-m).
  5. Rotate the engine 360 deg. and set the clearance on the remaining slave pistons.

Tools required

  • Jacobs feeler gauge P/N 16896 (Pre-91) or P/N 17902 (91) Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Pre-91 clearance 0.045 in. (1.14 mm)
  • 91 clearance 0.050 in. (1.27 mm)
  • Locknut 25 lbft. (35 N-m)