Home›Repair guides›Caterpillar›Control Valve Removal and Cleaning

Caterpillar C317 — Control Valve Removal and Cleaning

Maintenance

For the Caterpillar C317, from the Caterpillar service manual.

Browse Caterpillar generators & specs →

Before you start

  • Remove control valve covers carefully to avoid personal injury; control valve covers are under load from the control valve springs.
  • Be sure the control valve collar is installed with the longer sleeve area up. If the collar is installed upside down, engine damage may result.

Procedure

  1. Apply pressure on the control valve cover and rotate the retaining ring ears to the slot in the housing; remove retaining ring using retaining ring pliers.
  2. Slowly remove cover until spring pressure ceases, then remove the two control valve springs, insert, and collar.
  3. Using needle nose pliers, reach into the bore and grasp the stem of the control valve and remove it.
  4. Wash the control valves with approved cleaning solvent; push a wire into the hole in the base to ensure the ball check is free.
  5. Dry the valve with compressed air and wipe clean with a paper towel; thoroughly clean the control valve bore.
  6. Reassemble parts reversing the removal procedure.
  7. Rotate the retaining ring so that the ears are located away from the slot in the housing.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Replace control valve if ball check is stuck

Source: Caterpillar service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.