Before you start

  • Do not allow control module to be unmounted or tie wrapped behind the dash; control module will be stressed and failure will result.
  • Do not use body bolts or screws on the dash; a poor ground will cause intermittent engine brake operation and damage to the control module.

Procedure

  1. Mount the control module inside the cab so that the harness will reach the dash module, using two self-tapping screws.
  2. Connect the wire harness, P/N 015683, to the control module.
  3. Connect the wire harness, P/N 015684, to the Weatherpack connector on the control module.
  4. Connect the RED wire to a 10 amp circuit breaker controlled by the key switch.
  5. The ORANGE wire is for an anti-skid system; if not used, insulate the end and store the wire.
  6. Connect the BROWN wire to the 3176 electronic control module, connection P-8 terminal C.
  7. Connect the GREEN wire to a good ground at the dedicated ground connection point located at the cylinder head.

Specs & values

Source: Caterpillar service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.