Before you start

  • Corrosion of the metals can occur if the Quick Flush cleaning solution is in the cooling system for longer than 2 hours.

Procedure

  1. Drain the cooling system.
  2. Refill the cooling system to 90-94% capacity with acceptable quality water.
  3. Top off with Cat Cooling System Cleaner - Quick Flush so that the solution is 6-10% cleaner.
  4. Run the engine for 1.5 hours.
  5. After allowing adequate time for the system to cool, drain the cooling system.
  6. Flush the cooling system: fill with water, run engine 20 minutes, drain the water.
  7. Refill the cooling system with new coolant.

Specs & values

  • 6-10% cleaner solution
  • Run the engine for 1.5 hours

Source: Caterpillar manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.