Home›Repair guides›Caterpillar›Valve Adjustment Procedure

Caterpillar C-3406B / C-346 — Valve Adjustment Procedure

Adjustments · Engine valves and slave pistons

For the Caterpillar C-3406B / C-346, from the Caterpillar service manual.

Browse Caterpillar generators & specs →

Procedure

  1. With the engine at CYL. 1 TDC set the exhaust valves on cyl. 1, 3, 5, the intake valves on cyl. 1, 2, 4 and the slave pistons on cyl. 1, 3, 5.
  2. With the engine at CYL. 6 TDC set the exhaust valves on cyl. 2, 4, 6, the intake valves on cyl. 3, 5, 6 and the slave pistons on cyl. 2, 4, 6.
  3. Adjust the intake and exhaust rocker lever clearance to 0.015 in (0.38 mm) for intake and 0.030 in (0.76 mm) for exhaust.
  4. Torque the rocker adjusting screw lock nuts to 22 lbft (30 N·m).
  5. After setting exhaust valve clearance, with the exhaust valve closed and the bridge loose, set the slave piston clearance.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Intake lash 0.015 in (0.38 mm)
  • Exhaust lash 0.030 in (0.76 mm)
  • Lock nuts 22 lbft (30 N·m)

Source: Caterpillar service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Caterpillar repair guides →