Caterpillar 3126B — Cooling System Recommendations
Maintenance
For the Caterpillar 3126B, from the Caterpillar owner's manual.
Applies to: Caterpillar 3126B
Before you start
- DO NOT use commercial antifreeze with high silicate content formulated for gasoline engines.
Procedure
- Use only distilled or deionized water.
- Antifreeze must be a low silicate type that meets TMC RP329, ASTM D5345, or D4985 specifications. DO NOT use commercial antifreeze with high silicate content formulated for gasoline engines.
- Use conditioner or inhibitor to maintain a three to six percent concentration in cooling system. Requirements are different for ELC (Extended Life Coolant) — consult your dealer.
- Do not mix different antifreeze and conditioners.
- Cat ELC recommended for six-year protection. Meets Cat EC-1 specification.
Specs & values
- Conditioner or inhibitor concentration: three to six percent
Full service-parts list: Caterpillar 3126B →
Source: Caterpillar owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.