Home›Repair guides›Caterpillar›Fuel System - Prime

Caterpillar 3126B / 3126B Industrial Engine — Fuel System - Prime

Maintenance

For the Caterpillar 3126B / 3126B Industrial Engine, from the Caterpillar owner's manual.

Applies to: Caterpillar 3126B, Caterpillar 3126B Industrial Engine engine

Before you start

  • Fuel leaked or spilled onto hot surfaces or electrical components can cause a fire.
  • Do not crank the engine continuously for more than 30 seconds.

Procedure

  1. Engines with a fuel priming pump: open the fuel priming pump and operate until a strong pressure is felt. Lock the pump.
  2. Promptly start the engine. If the engine runs rough, continue operating at low idle.
  3. If the engine does not start, open the fuel priming pump and repeat.
  4. Engines without a priming pump: remove the plug to fill the fuel filter; ensure air can vent. Install and clean the plug.
  5. Start the engine and operate at low idle until the engine runs smoothly.

Full service-parts list: Caterpillar 3126B →, Caterpillar 3126B Industrial Engine engine →

Source: Caterpillar owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Caterpillar repair guides →