  1. Drain: stop engine, loosen filler cap, remove cap. Open drain cock or remove drain plug on engine and radiator. Allow coolant to drain.
  2. Flush: flush with clean water. Close drain. Fill with mixture of clean water and Caterpillar Fast Acting Cooling System Cleaner (0.5 L per 15 L capacity). Install cap.
  3. Run engine at low idle for at least 30 minutes. Coolant temperature at least 82 °C.
  4. Stop engine, drain, flush with clean water.
  5. Fill: close drain. Fill with coolant/antifreeze. Do not install cap.
  6. Start and run engine at low idle then high idle for one minute to purge air. Stop engine.
  7. Check coolant level within 13 mm below bottom of filler pipe.
  8. Inspect filler cap gasket; pressure test with 9S-8140 if not damaged. Install cap.
  9. Start engine and inspect for leaks.

Tools required

  • 9S-8140 Pressurizing Pump Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 0.5 L cleaner per 15 L capacity
  • 82 °C
  • 13 mm
  • 19 L/min fill rate

Source: Caterpillar owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.