CASE — Air Conditioning System Refrigerant Charging and Testing
A CASE service procedure — check it applies to your exact model before use.
Browse CASE generators & specs →
Before you start
- DO NOT USE OTHER REFRIGERANT TYPES
Procedure
- Pressure test the system using nitrogen to 250 psi. Check for leaks.
- Add 2oz SP20 Sanden PAG oil.
- Vacuum the system for at least 1/2 hour.
- Check that vacuum holds.
- Fill with 2.75-3 lbs R134a refrigerant.
- Test system and check thermostat cycling.
Tools required
- Pressure test equipment (nitrogen)
- Vacuum pump
Specs & torque values
- 2oz SP20 Sanden PAG oil
- 2.75-3 lbs R134a refrigerant
Source: manual:INST-K 570 MXT CASE.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.