Briggsandstratton.Com — Contact Point Inspection and Adjustment
A Briggsandstratton.Com service procedure — check it applies to your exact model before use.
Browse Briggsandstratton.Com generators & specs →
Before you start
- Do not use a steel file on contact points - use carborundum contact point file only
- If either or both points are badly pitted or burned, replace both points
Procedure
- Locate contact points on engine crankcase
- Turn crankshaft by hand to see if contact points open and close properly
- Points must be clean and line up squarely to make good electrical contact
- Do not use a steel file on contact points - use carborundum contact point file
- If either or both points are badly pitted or burned, replace both points
- Loosen contact spring bolt
- Move contact spring assembly to line up with contact arm
Tools required
- Carborundum contact point file
Specs & torque values
- Part Nos. 68288 and 59754 (replacement points)
Source: manual:A AP AR6-domestic.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.