Procedure
- 13. Set Digital Multimeter to read ohms.
- 14. See Figure C4. Connect one meter test lead to Wire 11, and the other to Wire 22. Measure
- 15. See Figure C5. Connect one meter test lead to Wire 22, and the other to Wire 44. Measure
- 16. Compare results obtained in steps 14-15. Based on meter quality, readings should be approximately
- A. Yes- Move to step 17.
- B. No- Low resistance indicates a shorted stator winding, while high resistance or infinity (OL) is an
- 17. See Figure C6. Connect one meter test lead to Wire 11, and the other to a proper engine ground.
- 18. See Figure C7. Connect one meter test lead to Wire 44, and the other to a proper engine ground.
- 19. Is a reading of infinity (OL) obtained in steps 17-18?
- A. Yes- Connect Wire 11 and Wire 44 to circuit breaker. Connect Wire 22 to neutral lug. Move to
Source: manual:Briggs_Air-CooledRepairManual80019677.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.