Briggs & Stratton — Test 5: Check Starter Relay Signal: Yes- Move to Test 6: Check Starter Solenoid Connection (step 23).
For these Briggs & Stratton models: 10 kW, 8 kW.
Browse Briggs & Stratton generators & specs →
Procedure
- 19. See Figure A9. Set Digital Multimeter to read DC volts. Remove Wire 56 from starter relay spade
- 20. Install 15 Amp fuse in control panel.
- 21. Press and hold MANUAL on control panel to start engine.
- 22. Measure DC voltage while control panel sends crank signal (approximately 10 seconds ON and 10
- A. Yes- See Figure A10 and Figure A11. Alternately check for same DC voltage at the positive (+)
Source: manual:Briggs_Air-CooledRepairManual80019677.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.